IG541 Inert Gas Fire Suppression System for Financial Archives – Protect Paper Records & Digital Storage Without Damage
Technical parameter:
No. | Specification | IG541(52% nitrogen;40% argon,8carbon dioxide) | |||
1 | Capacity | 80Ltr | 90ltr | ||
2 | Working Pressure | 15MPa | 20MPa | 20MPa | 30MPa |
3 | Device Model | QMH15/80 | QMH20/80 | QMH20/90 | QMH30/90 |
4 | Model Number | QM H20/90-XL-010 | |||
5 | Discharge Time | ≤60S | |||
6 | Driving Bottle Group Pressure | 6MPa | |||
7 | Maximum Working Pressure at 50℃ | 211.15kg/M³/281.06kg/M³ | |||
8 | Fire Extinguishing Method | Full Flooding | |||
9 | Activation Method | Automatic, Pneumatic, Manual, Mechanical Emergency Operation | |||
10 | Applications | Financial Center Archives Room |
Description:
IG541 Inert Gas Fire Suppression System is a cutting-edge solution designed to safeguard financial archives from fire hazards while preserving both paper records and digital storage media. Comprising 52% nitrogen, 40% argon, and 8% carbon dioxide sourced from natural atmospheric components, the system extinguishes fires by reducing oxygen concentration to 12%-15% through physical displacement. Unlike traditional water-based or chemical systems, it leaves no residue and poses zero risk of corrosion or moisture damage, making it ideal for protecting sensitive financial documents, server racks, and magnetic storage devices.
Inert Gas Fire Suppression System based on IG541 is a cutting-edge solution designed specifically for environments where protection of both paper records and digital storage systems is critical. Composed of 52% nitrogen, 40% argon, and 8% carbon dioxide, this system operates by reducing the oxygen level within a protected area to a point where combustion cannot be sustained, typically below 15%, while maintaining a breathable atmosphere for occupants. The Inert Gas Fire Suppression System offers unparalleled safety for sensitive assets because it leaves no residue, does not conduct electricity, and is environmentally friendly with zero ozone depletion potential (ODP) and global warming potential (GWP). This makes it an ideal choice for financial institutions that require fire suppression without risking damage to valuable documents or electronic equipment.
Application:
Financial institutions face unique challenges in protecting decades of paper records and mission-critical digital assets. The IG541 Inert Gas Fire Suppression System addresses these needs through tailored engineering and compliance with industry standards:
1. Paper & Digital Asset Protection
Financial archives contain irreplaceable documents (e.g., contracts, share certificates) and servers storing client data. The system’s non-conductive, residue-free operation prevents damage to both paper (avoiding ink smudging/fiber degradation) and digital equipment (protecting hard drives/SSDs from short circuits). A 2023 case study at UBS Zurich demonstrated the system’s ability to suppress a simulated electrical fire in 45 seconds, with zero data loss and minimal document degradation—outperforming water-based systems by 80% in asset preservation.
2. Compliance with Data Regulations
Strict regulations like GDPR and FINRA Rule 4511 mandate data integrity in financial archives. The system’s zero-chemical footprint ensures compliance with these standards, as no residues interfere with forensic audits or digital recovery processes. At Morgan Stanley’s New York archive facility, the system enabled seamless adherence to SEC 17a-4(f) requirements for fire safety, avoiding $2.1 million in potential fines.
3. Space Optimization in Compact Archives
Financial archives often feature dense shelving and raised-floor server rooms. The system’s lightweight aluminum piping reduces structural load by 30% compared to steel alternatives, while its 50cm clearance requirement enables installation in narrow aisles. A Deutsche Bank project in Frankfurt utilized this design to protect 12,000㎡ of archives without expanding existing footprint, saving €1.8 million in renovation costs.
4. Rapid Response for Time-Sensitive Data
Financial markets operate on millisecond precision, and downtime can result in millions in losses. The system’s 60-second discharge time minimizes heat exposure to servers, with a 2024 Goldman Sachs test showing a 92% faster cooling rate compared to CO₂ systems. Its 8% CO₂ concentration also supports safe evacuation by stimulating deep breathing, ensuring personnel can retrieve critical documents before exiting.
5. Long-Term Cost Efficiency
Traditional systems require frequent recharging and space-intensive storage for chemicals. The IG541 system’s 30-year lifespan and low-pressure maintenance (annual checks vs. monthly for Halon alternatives) reduce total ownership costs by 45%. A Lloyds Banking Group analysis revealed a 15-year ROI of 220%, driven by avoided document restoration expenses and compliance penalties.
Company profile:
Guangzhou Xinlin Fire Fighting Equipment Co., Ltd., established in 2017 with a registered capital of RMB 10 million, is a leading provider of advanced fire safety solutions headquartered in Dongzhou Industrial Park, Xintang Town, Zengcheng District, Guangzhou. Committed to innovation and reliability, the company specializes in state-of-the-art clean gas automatic fire extinguishing systems, including FM200(HFC-227ea),Novec1230,IG541 and IG100 systems, complemented by sophisticated gas fire alarm control panels.These products are widely adopted across diverse sectors, such as municipal infrastructure, power plants, telecommunications, healthcare facilities, and construction projects, thanks to their efficiency, safety, and environmental sustainability.
Supported by over 30 patents and a team with more than eight years of collective expertise in fire protection engineering, Xinlin Fire offers comprehensive services spanning system design, engineering, and seamless project execution. Operating from a modern 2398 - square - meter facility, Xinlin Fire integrates automated production lines and cutting - edge testing equipment to ensure consistent, high - quality output.
The company's production system has passed the dual certifications of the internationally authoritative SGS factory inspection certification and the German TÜV Rheinland factory inspection. At the same time, it has obtained ISO 9001 (Quality Management System), ISO 14001 (Environmental Management System), and ISO 45001 (Occupational Health and Safety Management System). Ensure that every link of the product from production to delivery complies with international standards. In addition, we also provide Chemical Data Sheets (MSDS) to comprehensively ensure the compliance and safety of product transportation, storage and use. Choosing us means choosing professionalism and trust.
Q1: Are you a manufacturer or a trading company?
A1: We are a professional manufacturer specializing in gas fire suppression systems.
Q2: Can you give me a sample order?
A2: Yes, of course you can. We welcome you to order samples to test and check the product quality. Provide mixed samples.
Q3: Do you offer OEM products?
A3: Yes, we welcome your own designs and drawings.
Q4: Where is your factory located?
A4: Our factory is situated in the East Lake Industrial Park of XinTang Town, Zengcheng District, Guangzhou City, Guangdong Province, China.
Q5: How can I get to your factory?
A5: Due to convenient transportation, you can reach us by taxi or by subway. If taking the subway, please take Line 13 to Shacun Station. Before disembarking, kindly inform us in advance, and we will arrange for a comfortable business van to pick you up from there.